VC2-5 Voltage Clamp

Online data sheet below

Description:

The VC2-5 Voltage Clamp is designed to condition the output of sensors that operate from a 5V supply.  The VC2-5 is designed to operate from the same +5V supply and ground that powers the sensor it connects to.  Under normal operating conditions, the VC2-5 outputs a signal that is identical to the signal present at its input.  When the voltage of the flow signal reaches the internally set clamp level, the VC2-5 maintains a constant output voltage at the clamp level as the input voltage rises.

The VC2-5 differs from the VC1 by offering a hard clamp function that is user adjustable.  The hard clamp allows the output to track the input right up to the clamp voltage.  Once in clamp, the VC2-5 maintains the clamp level with high accuracy regardless of overdrive. 

The VC2-5 is especially useful for forced induction conversions where a supercharger or turbocharger is fitted to an engine that is normally naturally aspirated.  Under boost the engine can generate higher flow or pressure levels than normal.  The clamping function of the VC2-5 maintains the input to the ECU within normal levels.  Throughout its entire tracking and clamping range, the VC2-5 always produces a clean, undistorted signal that the ECU can reliably read.

The VC2-5 allows the conversion to forced induction on engines with modern fuel injection including those with OBDII on-board diagnostics.  The stock ECU programming may be used without activation of fault codes under boost.

Features:

Hard clamp limits to a precise level
User adjustable from 2.5V to 5V
Can be ordered from the factory with a preset voltage
Avoids fault codes due to excess flow or pressure readings
Compatible with OBDII systems
Clean, undistorted output signal

Typical Connections:

Note: For highest accuracy, the Black wire should be tied to sensor ground.

Wire Assignments:

WIRE COLOR
CONNECT TO
LABEL
Red
+5V
+5
Black
Sensor ground
GROUND
Blue
MAP sensor output
MAP IN
Blue/White
MAP sensor input to the ECU
MAP OUT

Clamp Function (Fixed Internally):

Electrical Characteristics:

PARAMETER
CONDITIONS
MIN
TYP
MAX
UNITS
Supply Voltage

+5V to ground

4.5
5
13.5
V
Input Voltage
Signal Input to ground
 
 
9
V
Clamp Level
Signal Output to ground
 2.5
5
V
Input Resistance
Signal Input to ground
 
20
 
k
Output Resistance
Output to ground
 
100
 
Supply Current
+5V To ground
 
6
 
mA

Mechanical Characteristics:

(dimensions in inches)